The Melker kit manufactured by Cook Medical includes all the equipment necessary: catheter, thin-walled needle, Seldinger wire, cuffed tracheostomy tube 5.0 mm ID, and tapered introducer.
++
Identify the thyroid cartilage and the cricothyroid membrane directly caudally.
Prep the neck with suitable antiseptic; anesthetize the skin overlying the cricothyroid membrane with 1% lidocaine.
Isolate the trachea between the thumb and 3rd finger of the sterilely gloved nondominant hand, using the index finger to palpate the cricothyroid membrane landmark. With a syringe attached, preferably containing sterile water or remaining lidocaine, insert the catheter through the cricothyroid membrane at a 30-degree angle to the horizontal, aiming toward the feet. Once through the skin, begin aspirating as the catheter is advanced. Air and bubbles entering the syringe confirm entry into the trachea.
Carefully slide the catheter off of the needle and into the trachea.
Reattach syringe and reconfirm tracheal position.
...